Cement
The cement industry operates under some of the most demanding thermal and mechanical conditions. From preheaters and kilns to coolers and tertiary air ducts, each zone requires carefully engineered refractory materials to ensure efficiency, safety, and long-term reliability. At ARM, we provide cement producers with high-performance refractory linings tailored to resist abrasion, alkali attack, thermal shock, and intense operational loads.
By leveraging decades of field expertise and a broad range of proven materials, ARM helps minimize maintenance frequency, extend equipment lifespan, and reduce downtime. Our focus is on delivering tailored solutions that ensure consistent production output, even in the face of harsh chemical and thermal exposure.
Why ARM for your Refractory Solutions Partner?
We understand the critical role refractory performance plays in cement operations. That’s why ARM offers engineered solutions designed around your plant conditions, process zones, and turnaround schedules. We don’t just supply products—we support plant efficiency through technical advisory, smart product selection, and application-ready delivery.
- Custom solutions for each cement zone (preheater, kiln, cooler, etc.)
- Alkali-resistant and abrasion-resistant formulations
- Fast and safe installation support
- Optimized material lifecycle and thermal efficiency
- Reduced unplanned shutdowns and maintenance costs
- 1
- 2
- 3
Upper Cyclones
| Sections | Products |
|---|---|
| Working Lining | Hy-Cast LC 14 / Hy-Cast C14HR (G) |
| Insulation Lining | Hy-Cast LW 124 / Hy-Cast LW 124 (G) |
| Anchoring System | SS 301 |
Middle Cyclones
| Sections | Products |
|---|---|
| Working Lining | Hy-Cast LC 16 / Hy-Cast C15 HR (G) |
| Insulation Lining | Hy-Cast LW 124 / Hy-Cast LW 124 (G) |
| Anchoring System | SUS310 / 253 MA |
Lower Cyclones
| Sections | Products |
|---|---|
| Working Lining | Hy-Cast LC 16 / Hy-Cast C15 HR (G) |
| Insulation Lining | Hy-Cast LW 124 / Hy-Cast LW 124 (G) |
| Anchoring System | SUS310 / 253 MA |
- 1
- 2
Upper Calciner
| Sections | Products |
|---|---|
| Working Lining | Hy-Cast LC 14 / Hy-Cast C14 HR (G) |
| Insulation Lining | Hy-Cast LW 124 / Hy-Cast LW 124 (G) |
| Anchoring System | SS 310 / 253MA |
Lower Calciner
| Sections | Products |
|---|---|
| Working Lining | Hy-Cast LC 16 / Hy-Cast C15 HR (G) |
| Insulation Lining | Hy-Cast LW 124 / Hy-Cast LW 124 (G) |
| Anchoring System | SUS310 / 253 MA |
- 1
Castable Lining
| Sections | Products |
|---|---|
| Working Lining | Hy-Cast LC 16 / Hy-Cast C15 HR (G) |
| Insulation Lining | Hy-Cast LW 124 / Hy-Cast LW 124 (G) |
- 1
Castable Lining
| Sections | Products |
|---|---|
| Working Lining | Hy-Cast SIC 30 / Hy-Cast SIC 60 / Hy-Cast Gibcrete S |
| Insulation Lining | Hy-Cast LW 124 / Hy-Cast LW 124 (G) |
| Anchoring System | SS 310 / 253MA |
- 1
- 2
- 3
- 4
- 5
- 6
Edge Covering (Top Ring)
| Products | |
|---|---|
| Edge Covering (Top Ring) | TBD |
Slagline
| Products | |
|---|---|
| Working Lining | TBD |
| Back Filling | TBD |
| Safety Lining | TBD |
| Insulation Lining | TBD |
Sidewall and Bottom
| Products | |
|---|---|
| Working Lining | TBD |
| Back Filling | TBD |
| Safety Lining | TBD |
| Insulation Lining | TBD |
Filling Gap
| Products | |
|---|---|
| Filling Gap | TBD |
Well Block
| Products | |
|---|---|
| Well Block | TBD |
Seating Block
| Products | |
|---|---|
| Seating Block | TBD |
- 1
Burner Pipe
| Sections | Products |
|---|---|
| Normal Condition | Hy-Cast LC 16 / Hy-Cast Gibcrete S |
| Severe Condition | Hy-Cast SIC 30 / SIC 60 (with SS Steel Fibers) |
| Anchoring System | SS 310 / 253MA |
- 1
Castable Lining
| Sections | Products |
|---|---|
| Working Lining | Hy-Cast LC 17 / Hy-Cast Gibcrete / Hy-Cast Gibcrete S |
| Insulation Lining | Hy-Cast LW 124 / Hy-Cast LW 124 (G) |
| Anchoring System | SS 310 / 253MA / Ceramic Anchor Bricks |
- 1
- 2
Castable Lining (Hot Section)
| Sections | Products |
|---|---|
| Working Lining | Hy-Cast LC 17 / Hy-Cast Gibcrete S / Hy-Cast SIC 27 |
| Insulation Lining | Hy-Cast LW 124 / Hy-Cast LW 124 (G) |
| Anchoring System | SS 310 / 253MA / Ceramic Anchor Bricks |
Castable Lining (Cold Section)
| Sections | Products |
|---|---|
| Working Lining | Hy-Cast LC 16 / Hy-Cast LC 14 / Hy-Cast C14 HR (G) |
| Insulation Lining | Hy-Cast LW 124 / Hy-Cast LW 124 (G) |
| Anchoring System | SS 310 / 253MA / Ceramic Anchor Bricks |
- 1
- 2
- 3
Straight Duct
| Sections | Products |
|---|---|
| Brick Lining | Castable |
| Insulation Lining | Hy-Cast LW 124 / Hy-Cast LW 124 (G) |
Bend Portion
| Sections | Products |
|---|---|
| Castable | Hy-Cast C13 HR (G) / Hy-Cast C14 HR (G) |
| Insulation Lining | Hy-Cast LW 124 / Hy-Cast LW 124 (G) |
| Anchoring System | SS 310 / 253MA |
Damper and Damper Housing
| Sections | Products |
|---|---|
| Castable Lining | Hy-Cast LC 17 / Hy-Cast SIC 30 (with SS Fibers) |
| Anchoring System | SS 310 / 253MA |
- 1
- 2
- 3
- 4
- 5
- 6
Waste Heat Recovery 1
| Sections | Products |
|---|---|
| Working Lining | TBD |
| Anchoring system | TBD |
Waste Heat Recovery 2
| Sections | Products |
|---|---|
| Working Lining | TBD |
| Anchoring system | TBD |
Waste Heat Recovery 3
| Sections | Products |
|---|---|
| Working Lining | TBD |
| Anchoring system | TBD |
Waste Heat Recovery 4
| Sections | Products |
|---|---|
| Working Lining | TBD |
| Anchoring system | TBD |
Waste Heat Recovery 5
| Sections | Products |
|---|---|
| Working Lining | TBD |
| Anchoring system | TBD |
Waste Heat Recovery 6
| Sections | Products |
|---|---|
| Working Lining | TBD |
| Insulation Lining | TBD |
| Mortar | TBD |
| Anchoring system | TBD |
| Castable Expansion Joint | TBD |